UV Lamp, UV Light, Ultraviolet Light, UV Filter, Ultraviolet Sterilizer, Ultraviolet Disinfection
 
 
Water Tank Sterilization Got Questions About UV? Call Us at (949) 748-5990 or Use Our Live Support UV Disinfection
                Search    Create Account    Customer Login    Checkout    

My Shopping Cart now in your cart 0 items
   
Spacer
Renewable Energy

UV PRODUCT CATEGORIES
Gas Flow
woodworking Home
woodworking Process & Water Tank Sterilization
industrial UV Disinfection Systems
mass flow meters UV Oxidation Systems

CONTACT US
Gas Flow
  Phone: (949) 748-5990
  Fax:     (949) 748-5991
  Email:   Contact Us
Industrial Supplier Industrial Supplier
  UV Monkey
8915 Research Drive,
Suite 100, Irvine CA 92618 USA

UV Sterilization Equipment


 
Dust Collection Systems


UV Oxidation

Applications of Enviolet®:
UV Monkey uses Enviolet® technology for UV Oxidation. Enviolet® incorporates a performance regulated UV reactor with various chemical and process steps to provide optimal oxidation with low operating costs. All our UV Oxidation applications require ongoing evaluation - Please use our live support to discuss your requirements.

UV Oxidation Systems

45 GPM
(10 mm³/h) selective reactions

UV Oxidation
UV Oxidation Systems
CyanoMat®

Environmental Award of Berlin, 1999

Waste water and concentrates containing cyanide of up to 80g per liter of cyanide ions (CN-) are treated with this method. The detoxification is automatic, fast and safe. No AOX is produced during the treatment and all relevant regulatory parameters are met using this new method of treatment

  UV Oxidation Systems
UV Oxidation Systems

Electroless Nickel, Electroless Nickel Plating

We treat waste water and concentrates from electroless nickel plating processes, with and without ammonia, where nickel, phosphorous, COD and ammonia are treated to meet environmental discharge limits.

  Oxidizers
UV Oxidation Systems

Electroless Copper (Cu EDTA)

EDTA and other organic chelates are widely employed in electroless plating processes used in the PCB and metal finishing industries. The main concern about these compounds is their poor biodegradability. Chelates can still be present as much as 15 years after their disposal, with EDTA being among the most persistent. Restrictive legislation on the discharge of chelating agents and general organics is becoming ever more stringent.

  Electroless copper

 
UV Monkey has addressed the issues of treating chelated waste solutions with the application of advanced oxidation, the Komodo process uses hydrogen peroxide in combination with UV to produce hydroxyl radicals that subsequently oxidize species such as EDTA. The wastewater is free of EDTA and the COD is significantly decreased and can now be treated with conventional treatment techniques. Advanced oxidation yields a waste suitable for discharge that meets future regulations and greatly reduces operating costs compared with off site haulage or DTC treatment.
UV Oxidation Systems

Zinc Nickel, Zinc Nickel Plating

Our powerful and patented CyanoMat® reactor is capable of treating waste water and concentrates containing zinc-nickel. The treatment costs are considerably lower than that for external disposal, and are not feed concentration dependant.



 
UV Oxidation Systems

Oxidation of Aromatic Hydrocarbons

A custom engineered UV-Catalyst process has been developed for the elimination of aromatics. This method has a wide range of industrial applications.

  Ultraviolet
UV Oxidation Systems

Nickel Bath Conditioning

This is a breakthrough in plating technology. Equip your nickel baths with the latest technology and reduce operating costs through residue-free ‘cold’ burning of undesired organic material during production.

  Disinfection
UV Oxidation Systems

Recycling of Acid Copper Baths and Pulse Platin Baths for Pattern and Panel Plating

A UV evaporator has been developed to treat copper baths (acidic copper, pulse plating and special application). The system combines bath decontamination through the elimination of tramp organic species, combined with reuse of pre-concentrated rinse water. Users of this technology have benefited from lower reject levels by optimising bath operating conditions.


  UV Oxidation Equipment
UV Oxidation Systems

COD Oxidation, COD Reduction

The process applied for the oxidation of aromatics, is also ideally suited for the reduction of COD. Additional process steps provide the optimal operating conditions to yield a reduction in COD of more than 95%.

  Sterlization
Ultraviolet
Copyright (c) 2006, Komodo Enterprises, Inc. | Privacy Policy (last updated 11/29/06) | Conditions of Use | Contact Us
 fume extraction equipment

       Get The Monkey Factory Direct Your Source For Quality UV Equipment


Warning: include(/home/ductmonk/public_html/phpTrafficA/write_logs.php) [function.include]: failed to open stream: No such file or directory in /home/uvmonkey/public_html/includes/footer_english.php on line 71

Warning: include() [function.include]: Failed opening '/home/ductmonk/public_html/phpTrafficA/write_logs.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/uvmonkey/public_html/includes/footer_english.php on line 71